Summarize
1)Delay output: After the power supply is connected, there will be a time delay for 5-8s before operation;
2)Over and under voltage protection: If the output voltage is more than ±10%(±2%) higher/lower than the rated output value, the alarm gives off automatically and the power supply is cut automatically;
3)Over current and short circuit protection: When the set current is exceeded or short circuit is caused by over load, the power switch will trip out automatically;
4)Phase absence protection: Audible and visual alarm will be sent when phase absence exists and the power will be cut automatically;
5)Automatic inspection and diagnostic function: When hardware fails, the microprocessor will diagnose and send audible and visual alarm automatically;
6)Power network bypass function: When the voltage of electric network changes within ±4% of the rated voltage, the stabilizer will stop operation automatically except the microprocessor. Power network bypass function is enabled.
7)Double bypass function of commercial network: If the hardware fails or the fuse blows out and the voltage of electric network changes within 10% of the rated voltage, the power of stabilizer will be supplied under automatic bypass status; the “electric supply/voltage stabilization” bypass switch may be used to switch to commercial network bypass status manually under such condition.
8)Automatic temperature control function: When the temperature of the coil of isolating transformer exceeds +70℃, the automatic temperature controller will active the ventilation and heat emission function automatically.
9)Applicable load: Applicable to any load;
10)Anti surge property: A high performance surge shock suppressor is installed at the line input end to effectively eliminate fatal shock to equipment from pulse spike voltage within 10us-100us such as lightning induction.
| Type | Rated | Iout (A) | Uin | Uout (V) | No. of phases | (V) Withstand voltage | Insulated resistance (MΩ) | Efficiency | Waveform Deformation | Frequency | Precision of stabilization | Time of stabilizing |
| SBW-10 | 10 | 16 | 304-456 | 380±5% (can be set) |
3 phases | 1 min non- break | ≥2 | ≥98 | ≥0.1 | 50-60 | ±(1-5) (can be set) | If the different voltage value is 10% of rated input voltage, time of stabilizing will be shorter than 1.5s. |
| SBW-20 | 20 | 31 | ||||||||||
| SBW-30 | 30 | 46 | ||||||||||
| SBW-50 | 50 | 76 | ||||||||||
| SBW-100 | 100 | 152 | ||||||||||
| SBW-180 | 180 | 274 | ||||||||||
| SBW-225 | 225 | 342 | ||||||||||
| SBW-320 | 320 | 487 | ||||||||||
| SBW-400 | 400 | 608 | ||||||||||
| SBW-500 | 500 | 760 | ||||||||||
| SBW-600 | 600 | 912 | ||||||||||
| SBW-800 | 800 | 1216 | ||||||||||
| SBW-1000 | 1000 | 1520 | ||||||||||
| SBW-1200 | 1200 | 1824 | ||||||||||
| DBW-3 | 3 | 14 | 176-264 | 220±5% (can be set) | 1 phase | 1500 | ||||||
| DBW-5 | 5 | 23 | ||||||||||
| DBW-10 | 10 | 46 | ||||||||||
| DBW-20 | 20 | 91 | ||||||||||
| DBW-30 | 30 | 137 | ||||||||||
| DBW-50 | 50 | 228 | ||||||||||
| DBW-100 | 100 | 455 |
| No. of phases | Type | Capacity (KVA) | External dimension | Weight(kg) |
|
| ZSBW-10 | 10 | 1350X550X450 | 135 |
| ZSBW-20 | 20 | 1350X550X450 | 160 | |
| ZSBW-30 | 30 | 1350X550X450 | 170 | |
| ZSBW-50 | 50 | 1350X550X450 | 240 | |
| ZSBW-100 | 100 | 1450X850X550 | 350 | |
| ZSBW-180 | 180 | 1800X950X650 | 520 | |
| ZSBW-225 | 225 | 1800X950X650 | 610 | |
| ZSBW-320 | 320 | 2200X1100X700 | 810 | |
| ZSBW-400 | 400 | 2200X1100X700 | 890 | |
| ZSBW-500 | 500 | 2200X1200X750 | 1020 | |
| ZSBW-600 | 600 | 2200X1200X750 | 1120 | |
|
| ZDBW-3 | 3 | 355X200X450 | 18 |
| ZDBW-5 | 5 | 355X200X450 | 26 | |
| ZDBW-10 | 10 | 410X244X500 | 47 | |
| ZDBW-20 | 20 | 1100X550X350 | 120 | |
| ZDBW-30 | 30 | 1100X550X350 | 165 |
Using condition
Using condition
ZSBW and ZDBW series stabilizer should be used indoors be indoors, normal conditions are as follows:
①Environmental temperature: -15℃~+55℃;
②Sea level elevation: 4000m
③Relative humidity: 10%RH~90%RH
④Installation position: no such materials serious effects on the Insulation of stabilizer, as gases, steam, chemical deposition, dust, dirt, and other explosive and erosive medium;
⑤There is no serious fluctuation in installation position;
⑥If any of above conditions are not satisfied, it is suggested that user and WENLIDA arrange the installation.